GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II

Shenzhen Teveik Technology Co., Ltd.
Contact Now

GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II

  • 1
  • 2

Brand Name : Teveik

Model Number : T-1029

Certification : CE

Place of Origin : China

MOQ : 10PCS

Payment Terms : T/T, Western Union, MoneyGram,Paypal,L/C, D/A, D/P

Supply Ability : 50,000 pieces/week

Delivery Time : 5-7 days

Packaging Details : 1pc/box

Safety standard : GB15979-2002

Instrument classification : Class II

Display : LCD digital display screen

cuff fits arm circumferences : 13 to 17 inches

Accuracy : +/-3mmHg

Stethoscope : Single head stethoscope

Contact Now

Classical Blood Pressure Monitor Stethoscope With Sphygmomanometer Accurate Medical Examination Manually

Product Description
Name
manual aneroid sphygmomanometer with stethoscope
Display
LCD digital display screen
cuff fits arm circumferences
13 to 17 inches
Driver Battery
manual
Accuracy
+/-3 mmHg
Stethoscope
Single head stethoscope
Single package size
19.5X21X7 cm
GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II
GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II
GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II
GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II
Specification
1. Before the blood pressure meter is activated, check it first. The normal blood pressure meter usually refers to the “0”
position. After the pressure, the reaction is flexible and can still return to the “0” position.
2. Ask the person to be seated at the table and put the left arm on the table to maintain a comfortable posture.
3. Adjust the arm and be at the same height as the heart. If the height is not enough, you can put a cushion under the arm.
4. Flatten the arm band so that the middle part of the belt is facing the radial artery. The lower edge of the arm band is 2 to 3
cm on the elbow. The upper arm is not too tight or too loose. Generally, two fingers should be inserted under the sleeve. It is
appropriate to avoid affecting correctness.
5. Insert the stethoscope's head into the arm band and place it on the elbow's radial artery.
6. Slowly inflate the inner band with the latex ball, and pay attention to the monitoring. When the pulsation of the radial artery
disappears, the pressure is increased by 2.5 kPa-4 kPa (20 mmHg-30 mmHg) to stop pumping.
7. After the pressure is stopped, the air in the arm band is slowly released at a rate of 0.3 kPa to 0.6 kPa (2 mmHg to 4 mmHg)
per second, and the sphygmomanometer pointer is gradually lowered.
8. The pressure value indicated by the hands when the first beating sound heard by the stethoscope during the descent is the
systolic pressure.
9. When the beat sound is gradually increased and then turned into a noise, then the tone suddenly becomes boring and gradually
disappears. When the sound is not heard, it is diastolic pressure.
When measuring blood pressure, it should be repeated 2 to 3 times, and the obtained readings are averaged as blood pressure
values.
The back of the sphygmomanometer case is equipped with a metal hook that can be hung on the arm band for easier reading.
Blood pressure watch arm with Velcro, easy to attach
Please contact Jobby to get latest price,I will reply within 2 hour.Thank you!

Product Tags:

GB15979-2002 Blood Pressure Monitor Stethoscope

      

17in Blood Pressure Monitor Stethoscope

      

3mmHg Medical Blood Pressure Cuff

      
China GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II wholesale

GB15979-2002 17in Blood Pressure Monitor Stethoscope 3mmHg Class II Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Teveik Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0